• Single-Sample Micro-Osmometer -1
  • Single-Sample Micro-Osmometer -2
  • Single-Sample Micro-Osmometer -3

Single-Sample Micro-Osmometer

With the Osmo1 Single-Sample Micro-Osmometer, we’ve bundled together accurate and reliable osmolality measurement with ease-of-use for efficient patient sample analysis. With a 90 second test time and onboard QC charts the Osmo1 helps your laboratory stay productive.
Easily maintain regulatory compliance while ensuring the security and integrity of patient data with the Osmo1. Best for labs that process 10 or fewer samples per day or prefer a direct-draw instrument.
Model : OSMO1

1. Gold-standard freezing point depression method technology

2. Low sample volume requirements

3. Supports CAP, CLIA, and HIPAA compliance


Sample type    

Body fluids

Sample volume

20±1μL

Test time

90 seconds

Sample Capacity

Single sample

Unit

mOsm/kg H2O

Resolution

1 mOsm/kg H2O

Sample throughput

Can process 20 sample in less than 1 hour

Range

0-2000 mOsm/kg H2O

Accuracy2

0 to 400 mOsm/kg H2O: mean value 2 mOsm/kg H2O from nominal value(1 SD)

> 400 to < 1500 mOsm/kg H2O: 0.5% mOsm/kg H2O from normal value (1 SD)

> 1500 to 2000 mOsm/kg H2O 1% mOsm/kg H2O from normal value (1 SD)

precision2

(within run) 0 to 400 mOsm/kg H2O: standard deviation 2 mOsm/kg H2O

> 400 to < 1500 mOsm/kg H2O: coefficient of variation 0.5% mOsm/kg H2O

> 1500 to < 2000 mOsm/kg H2O: coefficient of variation 1% mOsm/kg H2O

Temperature effects3

Less than 1 mOsm/kg H2O per 5°C (9°F)ambient temperature change

Communication

On-board printer, USB 2.0 Type A port(2), USB 2.0 Type B Port(1), Ethernet 10/100, RJ45 Connector port(1)

Supported Languages

Simple Chinese, Czech, Danish, English, French, German, Greek, Italian, Japanese, Korean, Portuguese, Russian, Slovak, Spanish, Swedish, Turkish

Storage temperature

-20°C to +45°C (-40°F to +113°F)

Electrical voltage

100-240 VAC (50/60 Hz)

Power consumption

60W

Dimensions (D x W x H)

38 cm x 36 cm x 38 cm (15″ x 14″ x 15″)

Net weight

6.0 kg (29 lbs.)

1.Subject to change

2.Accuracy and precision (within run) specifications apply to Advanced Instruments standards and reference solutions. Performance at Reference Conditions: 20°C to 25°C (68°F to 77°F); 40 to 60% relative humidity

3.Operating Conditions: Temperature 18°C to 35°C (64°F to 95°F); 5 to 80% relative humidity (non-condensing)

4.Dimensions when Micro-Sample Test Kit is on the instrument


Related Products

OsmoPRO® MAX Automated Osmometer

OsmoPRO® MAX Automated Osmometer

Multi-Sample Micro-Osmometer

Multi-Sample Micro-Osmometer

Advanced Automated Osmometer

Advanced Automated Osmometer

Multi-Sample Micro-Osmometer

Multi-Sample Micro-Osmometer

Single-Sample Micro-Osmometer

Single-Sample Micro-Osmometer

Fiske® 210 Micro-Sample Osmometer

Fiske® 210 Micro-Sample Osmometer